Baer Industrie-Elektronik GmbH
Home Information Products News Systems Contact Sitemap
 
 
EXTENDED
SEARCH
    

AMR Interface Landis+Gyr E350

 M-Bus / RS485 AMR Interface Landis+Gyr E350

ComModul MBus
    
Montage     
 Brief description


Upgradable for future communication needs: flexible remote communication modules without breaking approval seal. The new series of modules for domestic use puts 
promises into practice, paving the way not only for multi-energy applications but also for new services in personal energy management. This specification details the operation and the electrical requirements for connection of an AMR module with M-Bus or RS485 data interface to the L+G E350 (ZxF series 100) meter.




 Versions

•    M-Bus AMR Interface E350 (Order number:  11961)
•    RS485 AMR Interface E350 (Order number: 11959)



 Compatible meters

•    ZCF110/120 single phase meter
•    ZMF110/120 multiphase meter
•    ZFF110/120 multiphase meter



Flyer M-Bus AMR Interface E350 (Filesize 326K)
Flyer RS485 AMR Interface E350 (Filesize 326K)
User Manual M-Bus AMR Interface E350 (Filesize 408K)
User Manual RS485 AMR Interface E350 (Filesize 414K)



 Technical Data

Housing: Polycarbonate housing with terminals for using with Landis+Gyr E350 meters (L+G ZxF domestic meters)
Degree of protection: IP52 (according to IEC 60529)
Protection class: 2
Dimensions: 165mm x 90mm x 33mm (W x H x D)
Nominal voltage: 230VAC (-20% / +15%) / 50Hz
connection spring for one phase: Live (L1) and Neutral (N) from meter
Power consumption: ca. 2,8W
Temperature range: -45°C to +65°C (operational)
-45°C to +90°C (storage temperature)
LED displays: 2 LEDs:      
green: Power                      
red: Error     
Interface: M-Bus (2 wires, passive) according to EN 13757-2 (physical layer)
or
RS485 (2 wires) according to ANSI/TIA/EIA-485-A-98, ISO-8482
max. 31 slaves
Baud rate: 2400, 4800 or 9600 baud; default: 9600 baud (fixed baud rate)
Data format: 7E1, 8N1, 8E1; default: 7E1
Transmission protocol: IEC 62056-21 (conform to VDEW2+) with fixed baud rate (OBIS Codes)
Buffer size: 745 Bytes
Rate input: Max. voltage: 230VAC (-20% / +15%)
max. current: 2mA
Pulse output: Wipe, according to DIN 42864 (S0 output)
max. voltage: 265VAC/DC
max. current: 50mA
min. voltage: 5VDC





to SURVEY of M-Bus

Relays
Modems
Data
Logger
Software
M-Bus/RS485
Special
Product
Family
Modules
Service
 

Top of Page

   Home    |    Information    |    Products    |    News    |    Service    |    Contact us    |    Sitemap

Copyright © Bär Industrie-Elektronik GmbH

Last Update 21.04.2011 at 14:09:45.