Baer Industrie-Elektronik GmbH
Home Information Products News Systems Contact Sitemap
 
 
EXTENDED
SEARCH
    

Interface 20 mA current loop active

   20mA aktiv   

   20mA aktiv   


Functional block diagram and brief description

Bild 20mA
20 mA current loop active

Active 20-mA current loop to connect to a pc.

The module can be delivered as a passive interface.

The In- and Outputs are not galvanicaly separated.

The cable lenght must be less than 1 km.
Multiple users per segment are allowed.




Pin assignment

Pin assignment 20mA aktiv



TTL/CMOS pin assignment (links)
 
    Pin           Name      
1
-
NC
2
-
NC
3
TxD
Input
4
RxD
Output
5
GND
 
6
VCC1
+ 5V
7
VCC2
+ 12V
Pin assignment (rechts)
 
    Pin           Name      
1
-
NA
2
-
NA
3
A
+
4
B
NC =  not connected  =  nicht angeschlossen
NA = not available  = nicht vorhanden



Recommended operating conditions and electrical characteristics

Galvanic separation of In- and Outputs     no
 
Input Voltage UEIN mind. 3 V
Input Current IEIN typ. 10 mA
Output Voltage UAUS max. 12 V
Supply Voltage VCC1 typ. 5 V
Supply Voltage VCC2 typ. 12 V